NILAI DIAGNOSTIK UJI TROPONIN I KUANTITATIF METODE IMMUNOKROMATOGRAFI

Authors

  • Siti Fatonah
  • Anik Widijanti
  • Tinny Endang Hernowati

DOI:

https://doi.org/10.24293/ijcpml.v14i1.920

Keywords:

sensitivity, specificity, AMI, a quantitative cTnI assay

Abstract

Cardiac troponins are the most sensitive and specific biochemical markers of myocardial damage but there is no standardization of
WHO for cardiac troponin I, resulting in a variability for diagnostic value. It is necessary to determine diagnostic value for a new kit
of troponin I. To evaluate a new quantitative immunochromatography assay for troponin I at a various cut off level. A cross sectional
study was conducted in 64 patients with acute myocardial infarction (AMI) and 55 non-AMI as control from February to September
2007. The level of cardiac troponin I (cTnI) was measured and determined it diagnostic value at a various cut off level. The sensitivity,
specificity, PPV and NPV of this assay were 91%, 91%, 92% and 89% at cut off level of 1,0 ng/ml (according to the kit), respectively.
The cut off of cTnI were divided into five levels: 0.8, 1.0, 1.2, 1.5, and 2.0 with the area under curve were 0.923, 0.908, 0.912, and
0.897, respectively. The sensitivity were 94%, 91%, 86%, 81% and 72%, respectively, the specificity were 91%, 91%, 96%, 98% and
98%, respectively. This rapid diagnostic test is sensitive and specific to diagnose an acute coronary syndromes.