Comparison of K2 and K3 EDTA Anticoagulant on Complete Blood Count and Erythrocyte Sedimentation Rate

Authors

  • Harida Zahraini Department of Clinical Pathology, Faculty of Medicine, Universitas Airlangga/Dr. Soetomo General Academic Hospital, Surabaya
  • Yulia Nadar Indrasari Department of Clinical Pathology, Faculty of Medicine, Universitas Airlangga/Dr. Soetomo General Academic Hospital, Surabaya
  • Hartono Kahar Department of Clinical Pathology, Faculty of Medicine, Universitas Airlangga/Dr. Soetomo General Academic Hospital, Surabaya

DOI:

https://doi.org/10.24293/ijcpml.v28i1.1735

Keywords:

Complete blood count, erythrocyte sedimentation rate, K2 EDTA, K3 EDTA

Abstract

The use of anticoagulants is one of the important pre-analytic factors in hematological tests. Both dipotassium (K2) andtripotassium (K3) Ethylene Diamine Tetraacetic Acid (EDTA) are widely used anticoagulants. International CouncilStandardization of Hematology (ICSH) and several researchers recommend the use of K2 EDTA due to its less hyperosmolareffect on blood cells compared to K3 EDTA. This study aimed to compare the results of Complete Blood Count (CBC) andErythrocyte Sedimentation Rate (ESR) using anticoagulant K2 EDTA and K3 EDTA. This study was an analytic observationalstudy with a cross-sectional design conducted from April to December 2018. The subject of the study were 103 healthyadults selected by consecutive sampling. Blood samples were collected in both anticoagulant tubes with a volume of 3 mLeach. Samples were tested twice, in the first 0 hours and the next 6 hours using Sysmex XN 1000 and Alifax Roller 20 LC.Kolmogorov-Smirnov test, paired T-test and Wilcoxon rank test were used for statistical analysis. The agreement testbetween both anticoagulants was carried out using the Bland Altman plot for parameters with a significant difference. Therewas a significant difference between both anticoagulants for the parameters of hemoglobin, hematocrit MCV, MCHC, RDW,PDW, MPV, PLC-R, and erythrocyte sedimentation rate in both the first and second tests. The agreement test using the BlandAltman plot showed that the difference in these parameters was within the Limit of Agreement (LOA) range of 95%. Thisstudy showed that there were differences in some parameters of complete blood count and erythrocyte sedimentation ratebetween the two anticoagulants (K2 K3 EDTA), but these differences were within the LOA range.

Downloads

Download data is not yet available.

Author Biographies

Harida Zahraini, Department of Clinical Pathology, Faculty of Medicine, Universitas Airlangga/Dr. Soetomo General Academic Hospital, Surabaya

Department of Clinical Pathology, Faculty of Medicine, Universitas Airlangga/Dr. Soetomo General Academic Hospital, Surabaya

Yulia Nadar Indrasari, Department of Clinical Pathology, Faculty of Medicine, Universitas Airlangga/Dr. Soetomo General Academic Hospital, Surabaya

Department of Clinical Pathology, Faculty of Medicine, Universitas Airlangga/Dr. Soetomo General Academic Hospital, Surabaya

Hartono Kahar, Department of Clinical Pathology, Faculty of Medicine, Universitas Airlangga/Dr. Soetomo General Academic Hospital, Surabaya

Department of Clinical Pathology, Faculty of Medicine, Universitas Airlangga/Dr. Soetomo General Academic Hospital, Surabaya

References

Narayanan S. Pre-analytical issues in hematology. Laboratoriums Medizin, 2003; 27(7-8): 243-8.

Lorenzo MS, Strasinger SK. Blood collection: A short rd course. 3 Ed., Philadelphia, FA Davis Company, 2016; 3-41.

Goossens W, Van Duppen V, Verwilghen RL. K2- or K3-EDTA: The anticoagulant of choice in routine hematology. Clin Lab Haematol, 1991; 13(3): 291-5.

England JM, Rowan RM, Van Assendelft OW, Bull BS, Coulter W, et al. Recommendations of the international council for standardization in hematology for ethylenediaminetetraacetic acid anticoagulation of blood for blood cell counting and sizing. Am J Clin Pathol, 1993; 100(4): 371-2.

Mehmood R, Muhammed RK, Hussain S, Sana A. Evaluation of dipotassium and tripotassium EDTA evacuated tubes for routine hematological testing. J Clin Lab Anal, 2018; 32(1): 2-5.

Ahn S, Cho S-M, Shin H, Lee K-A. Comparison of improvacuter EDTA tube with BD vacutainer EDTA tube for routine hematological analysis: Clinical significance of differences, stability study, and effects of K and K EDTA. J Lab Med Qual Assur, 2016; 38(2): 2 3 77-86.

Ricos C, Alvarez V, Cava F, Garcia-Lario JV, Hernandez A, et al. Current databases on biologic variation: Pros, cons and progress. This database was most recently updated in 2014. Scand J Clin Lab Invest [Internet]. 1 9 9 9 ; 5 9 : 4 9 1 - 5 0 0 . Available from : https://www.westgard.com/biodatabase1.htm (accessed June 20, 2020).

De la Salle B. Pre- and post-analytical errors in hematology. International Journal of Laboratory Hematology, 2019; 41: 170-6.

Banfi G, Salvagno GL, Lippi G. The role of Ethylenediamine Tetraacetic Acid (EDTA) as in-vitro anticoagulant for diagnostic purposes. Clin Chem Lab Med, 2007; 45(5): 565-76.

Gari MA. The comparison of glass EDTA Versus plastic EDTA blood-drawing tubes for complete blood count. Middle-East J Sci Res, 2008; 3(1): 32-5.

Wiwanitkit V. Effect of EDTA K2 and K3 anticoagulants on the complete blood count measured by hematological analyzer. Arch Hell Med, 2011; 28(6): 131-2.

Downloads

Submitted

2020-11-18

Accepted

2021-10-04

Published

2021-12-15

How to Cite

[1]
Zahraini, H., Indrasari, Y.N. and Kahar, H. 2021. Comparison of K2 and K3 EDTA Anticoagulant on Complete Blood Count and Erythrocyte Sedimentation Rate. INDONESIAN JOURNAL OF CLINICAL PATHOLOGY AND MEDICAL LABORATORY. 28, 1 (Dec. 2021), 75–79. DOI:https://doi.org/10.24293/ijcpml.v28i1.1735.

Issue

Section

Articles